红外光谱的产生是由于分子发生振动能级跃迁的过程中需要一定的能量,而这个能量通常是吸收了红外光才得到满足的。分子从一个能级跃迁到另外一个能级时,一般伴随着具有一定能量的电磁辐射的吸收或发射,该能量相对应的两个能级之间的能级差为ΔE=hν。当光源发射的光通过某种气体时,如果该频率下一个光子具有的能量正好和气体分子的某两个特定能级之间的能量差相等,那么气体分子就选择性地吸收该频率下的光子,致使通过该气体介质后的光强变弱。所以特定的气体只能吸收与之相对应某个特定波长的光,这便是气体的选择吸收理论。利用气体分子选择吸收红外光谱的技术,可通过对某个特定频率下光强的检测来达到测量待测气体体积分数的目的。
-
一块厚度为L均匀的吸收介质,其各向同性,一束平行光波垂直的照射在该介质的表面,其初始光强为I0,在穿过该吸收介质之后,因为介质的分子会对光波产生选择性的吸收,从而导致该平行光波的强度减小为It。比尔-朗伯定律[16]表达式如下:
$ {I_{\rm{t}}} = {I_0}{\rm{exp}}\left[ { - \gamma \alpha \left( v \right)CL} \right] $
(1) 式中, γ是与传感介质相关的相对灵敏度因子,α(ν)是被测气体的吸收系数,ν是入射光波的频率,C是被测气体的体积分数,L是被测气体的有效吸收距离。整理得:
$ C = {\left[ {\gamma \alpha \left( v \right)L} \right]^{ - 1}}{\rm{ln}}({I_0}/{I_{\rm{t}}}) $
(2) 从(2)式可以看出, 当气体的种类确定了,α(ν)也就已知了,只要测量出光束穿过待测气体前后的光强I0和It以及有效吸收距离L,就可以通过计算得知C的大小。由于在近红外区域内,气体分子对光的吸收表现为弱吸收,使得α(ν)L≪1,则可对(1)式进行近似处理,表达式如下:
$ {I_{\rm{t}}} = {I_0}\left[ {1 - \gamma \alpha \left( v \right)CL} \right] $
(3) 由(3)式可得透射光强的相对变化量Ir为:
$ {I_{\rm{r}}} = ({I_0} - {I_{\rm{t}}})/{I_0} = \gamma \alpha \left( \nu \right)LC $
(4) 由(4)式可知,α(ν)和L一定时,透射光强的相对变化量Ir与气体的体积分数C的关系表现为线性。
-
高分辨率分子吸收数据库(high-resolution transmission molecular absorption database, HITRAN)[17]由美国的空军地球物理实验室研发,并详细地记录了47种气体分子的吸收谱线的相关信息。
从(2)式获知吸收系数α(ν)对于求得体积分数的值C是非常重要的,α(ν)可以通过计算吸收线强度与线型函数之间的乘积来求得。所以如何选择出恰当的CO2吸收谱线,对于能否准确地测量出CO2气体的体积分数非常关键。CO2的吸收谱线选取应该以下述几个原则作为基本的依据:(1)尽可能地选取吸收线强度比较大的吸收谱线,使得CO2气体能够充分吸收光信号;(2)为了避开背景气体的干扰,所选择的CO2吸收谱线应远离背景气体的吸收区域,这样才能够准确地对CO2的体积分数进行检测;(3)参考所用光源的发射波段对吸收谱线的位置进行选择,使所选的吸收谱线位于激光器的可发射波段范围之内。
只要按照上述3个基本原则,并且以实验室的真实环境作为参考,选择出适当的CO2吸收谱线,就能获得更好的实验结果。
查阅HITRAN数据库获得CO2在近红外波长段的吸收谱线图,如图 1所示。
查阅HIRTRAN数据库和图 1所示的CO2谱线分布图可知,在近红外区,CO2在波长为1572nm~1574nm波段的吸收线强度较大(如图 2所示),而且可以与实验时所使用的背景气体N2分开,同时也符合激光器的发射波段。因此本实验中主要在该波段对CO2体积分数进行检测,并绘制了吸收光谱图。
-
检测系统如图 3所示。光源为NETTEST可调谐光源,光谱检测装置是型号为MS97120B的光谱仪。
吸收池为一根长为9m的空芯光子晶体光纤,其横截面的结构如图 4所示。它是由丹麦的NKT公司设计生产的型号为HC-1550-02的HC-PCF,其传输光波的中心波长位于1550nm。它的纤芯是一个比较大的空气孔,该空气孔的直径是10μm±1μm,它的包层区域是由结构为六边形的空气柱通过周期性的排列而形成的光子晶体,所有空气孔区域的面积超过整个横截面的90%,包层的半径是60μm,色散大小是97ps·nm-1·km-1,在中心波长1550nm处传输损耗低于30dB/km。气室是金属圆柱状结构,它的直径是250mm,高度是200mm,体积是10L。在气室内部将单模光纤(single mode fiber, SMF)和多模光纤(multi mode fiber, MMF)分别与PCF固定连接在3维支架上,连接处留有约为20μm的缝隙,以使气体扩散进光子晶体光纤。
实验是在密闭常温环境下进行的。首先在气室1内充入CO2, 使气室1内气压达到0.2MPa,接着用真空泵把气室2内的气压抽至-0.08MPa,以此在两个气室之间形成压强差来加快气体扩散进光子晶体光纤[18]。经过5.5h左右待气体完全扩散进入到光子晶体光纤,然后从波长为1572nm开始,以波长0.02nm为间隔调谐光源至1573.4nm结束,同时记录光谱仪的光功率,最后由测量的数据绘制出吸收光谱图。
-
实验中采用图 3所示传感系统来完成对CO2体积分数的检测。由于气体传感检测在实际的应用过程中,一般在常温、常压的环境下进行,因此设定该检测系统的温度为25℃。图 5~图 8分别是该传感系统测得CO2体积分数为1, 0.10, 0.05和0.02时的光谱吸收图。分析比较图 5~图 8与图 2中CO2吸收峰的位置可以得知,图 5~图 8中位于吸收峰的几个波长的位置与图 2中有较高吸收线强度的波长位置基本吻合,而且都是在波长为1573.3nm附近达到最大,说明该检测方法能有效地对CO2进行检测。通过对比发现吸收峰的位置有一定的偏差,这主要是受光源波动和系统噪声及温漂的影响。分析比较图 5~图 8的CO2吸收光谱图可以看出,当CO2体积分数减小时,出现在1573.3nm附近的吸收峰位置比较稳定而且峰值最小,因此选择该波长下的吸收谱线能够更好地对较低体积分数CO2进行传感检测。
对CO2体积分数变化进行检测时,每次实验都要用待测气体反复冲刷气室1,消除之前实验残留气体的影响。图 9为CO2的吸收测量曲线。由该曲线可以知道, 光强相对变化量Ir和CO2气体体积分数C之间的关系呈线性变化,上述结果与之前的理论分析产生的结果一致。最后求得经线性拟合产生的曲线表达式为y=0.03308+0.01463x。
在相同实验条件下,充入不同体积分数的CO2进行多次测量,获得的测量值Cm与标准值Cs的对比见表 1。
Table 1. Comparison of the experimental value and the standard value of CO2 volumn fraction
Cs 0.02 0.05 0.10 Cm 0.0205 0.0511 0.1024 根据表 1中的结果计算实际相对误差为:
$ \sigma = ({C_{\rm{m}}} - {C_{\rm{s}}})/{C_{\rm{s}}} \times 100\% $
(5) 由(5)式可知, 系统的最大相对误差为2.4%。造成该误差的主要原因是:理论分析时对公式进行的近似处理以及光源波动、系统噪声的影响。
可通过计算输出光强的变化量与CO2体积分数的变化量之间的比值得出该系统的灵敏度S,即:
$ S = \Delta I/\Delta C = - \alpha {I_0}L $
(6) 从(6)式可以看出, 当初始光强I0和气体的有效吸收距离L一定时,系统检测灵敏度的大小只和被测气体的吸收系数α有关。因此对于待测气体为混合型多种气体时,只要每种被测气体选取吸收强度较高且不与其它被测气体相重合的吸收线,就可以做到高灵敏度检测混合气体中每种组分的体积分数。
从图 9中所示的拟合曲线求得该曲线的斜率αL= 0.01463,由于测量时系统的初始光强I0=3mW,因此求得该检测系统的灵敏度S=4.389×10-5W。
光子晶体光纤CO2气体传感器的研究
Research of CO2 gas sensors based on photonic crystal fiber
-
摘要: 为了能高灵敏度地检测CO2气体的体积分数,基于红外光谱吸收原理,设计了一种以9m长的空芯光子晶体光纤作为传感单元的CO2气体传感器。利用该传感器测量了不同体积分数的CO2在同一吸收波长下的吸收光谱图。结果表明,气体的吸收光强和气体的体积分数之间呈线性变化,与比尔-朗伯定律一致;传感器的灵敏度可达4.389×10-5W。可通过加长光子晶体光纤的长度,来增加气体吸收的有效距离,使传感系统获得较高灵敏度。Abstract: In order to get high sensitivity detection of volume fraction of carbon dioxide gas, a carbon dioxide gas sensor based on the principle of infrared spectrum absorption was designed by using 9m hollow-core photonic crystal fiber as sensing unit. The absorption spectra of carbon dioxide gas with different volume fractions were measured under the same absorption wavelength. The analysis results show that the linear relationship between gas absorption intensity and volume fraction of gas is presented, in accordance with Beer-Lambert law. The detective sensitivity of the system is estimated to be 4.389×10-5W. It can make the system get higher sensitivity by lengthening the photonic crystal fiber and increasing the effective distance of gas absorption.
-
Key words:
- sensor technique /
- sensitivity /
- infrared spectrum absorption /
- photonic crystal fiber
-
Table 1. Comparison of the experimental value and the standard value of CO2 volumn fraction
Cs 0.02 0.05 0.10 Cm 0.0205 0.0511 0.1024 -
[1] YANG M L. Research on the key technology of three-gas infrared optical sensor[D]. Taiyuan: North University of China, 2015: 2-6(in Chinese). [2] HE B C. Research of infrared spectrum based CO gas concentration detection system[D]. Hangzhou: China Jiliang University, 2014: 4-8(in Chinese). [3] HOU J F, PEI L, LI Zh X, et al. Development and application of optical fiber sensing technology[J].Electro-Optic Technology Application, 2012, 27(1):49-53(in Chinese). [4] ZHANG K K. Research on the spectrum absorptive optical gas detection theory and technology[D]. Harbin: Harbin Engineering University, 2012: 2-5(in Chinese). [5] CORDEIRO C M B, SANTOS E M D, CRUZ C H B. Lateral access to the holes of photonic crystal fibers-selective filling and sensing applications.[J].Optics Express, 2006, 14(8):8403-8412. [6] HUMBERT G, KNIGHT J C, BOUWMANS G, et al. Hollow core photonic crystal fibers for beam Delivery[J]. Optics Express, 2004, 12(8):1477-1484. doi: 10.1364/OPEX.12.001477 [7] LIU X L, TIAN C P, WANG Y Y. Fiber core design and property research of hollow-core photonic crystal fibers[J]. Journal of Beijing University of Technology, 2015, 41(12):1861-1866(in Chinese). [8] HANSEN T P, BROENG J, JAKOBSEN C, et al. Air-guiding photonic bandgap fibers:spectral properties, macrobending loss and practical handling[J]. Journal of Lightwave Technology, 2004, 22(1):11-15 doi: 10.1109/JLT.2003.822833 [9] MURAO T, SAITOH K. Realization of single-moded broadband air-guiding photonic bandgap fibers[J]. IEEE Photonics Technology Letters, 2006, 18(15):1666-1668. doi: 10.1109/LPT.2006.879546 [10] DING W H. Investigation of photonic crystal fiber sensor[D]. Beijing: Beijing Institute of Technology, 2014: 5-12(in Chinese). [11] JING L. Research on novel gas sensors with photonic crystal fibers[D]. Tianjin: Tianjin University, 2012: 95-99(in Chinese). [12] CUBILLAS A M, UNTERKOFLER S, EUSER T G, et al. Chem inform abstract:Photonic crystal fibres for chemical sensing and photochemistry[J]. Chemical Society Reviews, 2013, 42(22):8629-8648. doi: 10.1039/c3cs60128e [13] WU B Q. Research on active intra-cavity gas sensor with photonic crystal fiber[D]. Tianjin: Tianjin University, 2014: 40-53(in Chinese). [14] CHEN D F, LU P, LIU D M. Highly sensitive curvature sensors based on polarization-maintaining photonic crystal fibers[J]. Laser Technology, 2015, 39(4):450-452(in Chinese). [15] CHEN H. Research on optical fiber gas sensor based on HC-PCF and its networking technology[D]. Tianjin: Tianjin University, 2013: 43-45(in Chinese). [16] DEMTRODER W. Laser spectroscopy-basic conecpts and instrucmentation[M]. Beijing:Book World Publishing, 2002:11-15. [17] ROTHMAN L S.The hitran molecular spectroscopic database:edition of 2000 including updated through 2001[J].Journal of Quantitative Spectroscopy and Radiative Transfer, 2003, 82(1/4):5-44. [18] CUI J H, DING H, LI X L, et al. Acetylene sensing system using hollow-core photonic crystal fiber as gas cell[J].Acta Optica Sinica, 2010, 30(8):2262-2266(in Chinese). doi: 10.3788/AOS