Advanced Search

ISSN1001-3806 CN51-1125/TN Map

Volume 33 Issue 5
May  2010
Article Contents
Turn off MathJax

Citation:

Transmission characteristics measurement system of fiber laser devices in high power density

  • In order to improve the measurement accuracy of the transmission characteristics of the parts in high power fiber laser,an automated measurement system of power ratio was designed by means of the dual optical path measuring system with full consideration of the standard transmission measuring methods.The dual optical path measuring system was analyzed.With the measuring system equipped with a microchip solid laser and a unique refractive index matching cladding mode filter,the transmission loss of a double clad fiber laser was measured.In experiment,for a 35m of Yb-doped double cladding fiber its insert loss was 2.645dB at 1064nm and standard deviation is 0.026dB for 100 test data.Moreover,the repeated measurement error was less than 0.07dB proven by the experiments under different conditions.The result is useful to improve the measurement accuracy.
  • 加载中
  • [1]

    ZENG H F,XIAO F H.The development of Yb-doped double-clad fiber laser and its application[J].Laser Technology,2006,30(4):438-444(in Chinese).
    [2]

    LOU Q H,ZHOU J,WANG Zh J.Analysis of high-power fiber laser weapons[J].Laser Technology,2003,27(3):161-165(in Chinese).
    [3]

    LI Ch,YAN P,CHEN G,GONG M L.Using China-made Yb-doped double-clad fiber for fiber laser output power breakthrough 700W[J].Chinese Journal of Lasers,2006,33(6):738(in Chinese).
    [4]

    WANG R X.Number study on the coupling loss of the photonic crystal fiber[J].Laser Technology,2007,31(5):494-495(in Chinese).
    [5]

    GUO Y,CAO M C,LUO Zh X,et al.Design of multifunctional instrument of insert loss and return loss measurement[J].Laser Technology,2007,31(5):548-550(in Chinese).
    [6]

    Wuhan Post and Telecommunications Science and Technology Institute.GB/T 15972.4-1998 Generic specification for optical fibres part 4:measuring methods for transmission and optical characteristics[S].Beijing:Chinese Standards Press,1998:1-33(in Chinese).
    [7]

    RABAH A,JACQUES M.Mode scrambler for polymer optical fibers[J].Opt Engng,2000,39(1):299-303.
    [8]

    Wuhan Post and Telecommunications Science and Technology Institute.YD/T 893-1997 Technical conditions for fiber coupler[S].Beijing:Chinese Standards Press,1997:1-47(in Chinese).
    [9]

    HUANG B C,NING D,HAN J,et al.Study of ytterbium-doped double-clad fiber absorption characteristics[J].Chinese Journal of Lasers,2005,32(11):1472-1477(in Chinese).
    [10]

    VAYSHENKER I,LEHMAN J H,LIVIGNI D J,et al.Trilateral optical powermeter comparison between NIST,NMIJ/AIST and METAS[J].Appl Opt,2007,46(5):643-647.
    [11]

    ZENG Z Q.Three methods of realization serial communication between single chip and PC based on visual C++ platform[J].Automation and Instrumentation,2005,9(3):60-65(in Chinese)
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(4785) PDF downloads(150) Cited by()

Proportional views

Transmission characteristics measurement system of fiber laser devices in high power density

    Corresponding author: GONG Ma-li, gongmali@mail.tsinghua.edu.cn
  • 1. State Key Laboratory of Tribology, Center for Photonics and Electronics, Department of Precision Instruments and Mechanology, Tsinghua University, Beijing 100084, China

Abstract: In order to improve the measurement accuracy of the transmission characteristics of the parts in high power fiber laser,an automated measurement system of power ratio was designed by means of the dual optical path measuring system with full consideration of the standard transmission measuring methods.The dual optical path measuring system was analyzed.With the measuring system equipped with a microchip solid laser and a unique refractive index matching cladding mode filter,the transmission loss of a double clad fiber laser was measured.In experiment,for a 35m of Yb-doped double cladding fiber its insert loss was 2.645dB at 1064nm and standard deviation is 0.026dB for 100 test data.Moreover,the repeated measurement error was less than 0.07dB proven by the experiments under different conditions.The result is useful to improve the measurement accuracy.

Reference (11)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return