Focal switch of cosine-squared Gaussian beams passing through an astigmatic lens

  • In order to analyze the focal switch phenomena of cosine-squared Gaussian beams passing through an astigmatic lens,the expression for the axial irradiance distribution of focused cosine-squared Gaussian beams was derived based on the Collins formula.By means of numerical calculation,effect of astigmatic parameter on the axial irradiance was obtained.The dependence of the relative focal shift on the astigmatic parameter was studied at different positions of the beam's incident plane for a particular beam parameter and Fresnel number; the range of the beam's incident position of dual focal switches under this condition was determined and the focal switch due to the astigmatism was interpreted.
  • 加载中
  • [1]

    QIAO Y L,YANC Sh Zh,LUO R Zh,et al.Research on polarned spectral monitoring for remote sensing of earth[J].High Technology Letters,2001,11(7):36-39 (in Chinese).
    [2]

    SUN X B,HONG J,QIAO Y L.A method ofimage feature extraction based angle of polarization[J].Remote Sensing Technology Application,2005,20(2):256-260(in Chinese).
    [3]

    DESCHAMPS P Y,HERMAN M,PODAIRE A,et al.The POLDER instrument:misaion objectives[J].Proceedings of SPIE,1992,1746:72-91.
    [4]

    DEUZE J L,BREON F M,DESCHAMPS P Y,et al.Polarization measurements with the airbome version of the POLDER instrument[J].Ptoceedings of SPIE,1992,1747:178-187.
    [5]

    DINER D J,CHIPMAN R A.An integrated multiangle,multispectral,and polarimetric imaging concept for aerosol remote sensing from space[J].Proceeding of SPIE,2005,5659:88-96.
    [6]

    DEUZE J L,GOLOUB P,HERMAN M,et al.Aerosol retrieval using the POLDER instrument preliminary results[J].Ptoceedings of SPIE,1997,3121:347-355.
    [7]

    CAIRNS B,EDCAR E R,JOSEPH D L,et al.Research scanning polarimeter and airbome usage for remote sensing of aeroaols[J].Proceedings of SPIE,2003,5158:33-44.
    [8]

    TRAVIS L D.Remote sensing of aerosols with the earth obsewing scanning polarimeter[J].Proceedings of SPIE,1992,1747:154-164.
    [9]

    CHEN L G,HONG J,QIAO Y L,et al.Accuracy analysis on a sort of polarized measurement in remote sensing[J].Spectroscopy and Spectral Analysis,2008,28(10):2384-2387 (in Chinese).
    [10]

    LUO R Z,QIAO Y L,DUAN L F.Polarization analysis of optical system in airborne multi-band polarization CCD camera system[J].Proceedings of SPIE,2003,4891:442-448.
    [11]

    WALUSCHKA E,SILVERCIATE P,FTACLAS C,et al.Polarization sensitivity analysis of an earth remote sensing instrument:the MODIS-N Phase B study[J].Proceedings of SPIE,1992,1746:96-103.
    [12]

    CAO H,SONG L K,PENC H D,et al.The study of the relationship between polarized light's incident azimuth and intermediary reflectance[J].Laser Technology,2005,29(1):104-105 (in Chinese).
    [13]

    CHEN L G,HONG J,QIAO Y L,et al.Accuracy analysis of polarimetric measurement based on double Wollaston prisms[J].Laaer Technology,2008,32(5):468-470 (in Chinese).
    [14]

    CHIPMAN R A,The mechanics of polartion ray tracing[J].Proceedings of SPIE,1992,1746:62-75.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3831) PDF downloads(620) Cited by()

Proportional views

Focal switch of cosine-squared Gaussian beams passing through an astigmatic lens

    Corresponding author: MU Guo-qiang, xqwang@home.swjtu.edu.cn
  • 1. College of Physical Science and Technology, Southwest Jiaotong University, Chengdu 610031, China

Abstract: In order to analyze the focal switch phenomena of cosine-squared Gaussian beams passing through an astigmatic lens,the expression for the axial irradiance distribution of focused cosine-squared Gaussian beams was derived based on the Collins formula.By means of numerical calculation,effect of astigmatic parameter on the axial irradiance was obtained.The dependence of the relative focal shift on the astigmatic parameter was studied at different positions of the beam's incident plane for a particular beam parameter and Fresnel number; the range of the beam's incident position of dual focal switches under this condition was determined and the focal switch due to the astigmatism was interpreted.

Reference (14)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return