Dual-wavelength design of high precision rhomb-type achromatic retarders

  • Received Date: 2011-09-29
    Accepted Date: 2011-12-09
  • In order to improve the precision of rhomb-type achromatic retarders,according to the optical refraction rule and based on that the sum of the angle of total reflection θ and the reflection angle r is constant,dual-wavelength design was analyzed for two different wavelength beams incident on the retarder.Since the delay errors were the positive and negative,retardation was 90° at two wavelengths in the whole region of spectrum.Simultaneously,achromatic precision of the λ/4 retarder was enhanced greatly after optimum design for two wavelengths.The maximal delay error was smaller than 0.02° for a λ/4 retarder designed with LaK2 glass within the range of 360nm~1160nm.Compared with other two designing methods,the new designed retarder not only simplifies the designing theory,but also has higher achromatic precision,and the results are helpful to the design of high precision rhomb-type achromatic retarders.
  • 加载中
  • [1]

    YUN M J,LI G H,WANG M,et al.Three-in-one composite achromatic λ/4 wave-plate[J].Journal of Optoelectronics · Laser,2001,12(6):562-564 (in Chinese).
    [2]

    McINTYRE C M,HARRIS S E.Achromatic wave plates for the visible spectrum[J].Journal of the Optical Society of America,1968,58(12):1575-1580.
    [3]

    YE Ch.Coustruction of an optical rotator using quarterwave plate and optical retarders[J].Optical Engineering,1995,34 (10):3031-3035.
    [4]

    SONG L K,LI G H.Design of the three-element combination achromatic retarder made of mica and quarz[J].Jornnal of Optoelectronics ·Laser,2000,11 (1):51-53 (in Chinese).
    [5]

    LI J Zh.Optical handbook[M].Xi' an:Science and Technology Press of Shaanxi,1986:576-580 (in Chinese).
    [6]

    LI GL,SONG LK,HAO D Zh,et al.Optical design of rhomb-type achromatism retarder[J].Laser Technology,2006,30 (5):539-540(in Chinese).
    [7]

    LI G L,SONG L K,HAO D Zh,et al.Sensitivity of rhomb-type phase retarders to the input angle[J].Laser Technology,2008,32 (2):157-158(in Chinese).
    [8]

    ZHAO P T,LI G H,WU F Q.New design of high precision achromatic phase retarder[J].Acta Optica Sinica,2005,25(7):980-983 (in Chinese).
    [9]

    LI G L,SONG L K,FAN K M.Optimization of high precision rhombtypc achromatic retarder[J].Laser Technology,2011,35 (2):275-277(in Chinese).
    [10]

    NAGIB N N,E-BAHRAWY M S.Phase retarders with variable angles of total internal reflection[J].Applied Optics,1994,33 (7):1218-1222.
    [11]

    NAGIB N N.Phase retarders highly insensitive to the input angle[J].Applied Optics,1998,37(7):1231-1235.
    [12]

    YAO Q J.Study course of optics[M].Beijing:Higher Education Press,2002:155(in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3403) PDF downloads(748) Cited by()

Proportional views

Dual-wavelength design of high precision rhomb-type achromatic retarders

  • 1. Department of Physics, Xingyi Normal University for Nationalities, Xingyi 562400, China

Abstract: In order to improve the precision of rhomb-type achromatic retarders,according to the optical refraction rule and based on that the sum of the angle of total reflection θ and the reflection angle r is constant,dual-wavelength design was analyzed for two different wavelength beams incident on the retarder.Since the delay errors were the positive and negative,retardation was 90° at two wavelengths in the whole region of spectrum.Simultaneously,achromatic precision of the λ/4 retarder was enhanced greatly after optimum design for two wavelengths.The maximal delay error was smaller than 0.02° for a λ/4 retarder designed with LaK2 glass within the range of 360nm~1160nm.Compared with other two designing methods,the new designed retarder not only simplifies the designing theory,but also has higher achromatic precision,and the results are helpful to the design of high precision rhomb-type achromatic retarders.

Reference (12)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return