Reconstruction quality enhancement of computer generated hologram based on digital micro-mirror device

  • Corresponding author: ZHANG Ya-ping, yaping.zhang@gmail.com
  • Received Date: 2012-12-04
    Accepted Date: 2013-01-04
  • In order to achieve high-quality hologram reconstruction based on digital micro-mirror device(DMD), gray scale adjustment characteristics and Fresnel diffraction characteristics of DMDs were described in detail. Then, the principle of holographic display based on DMD was analyzed. Finally, high-quality hologram was reconstructed. The results demonstrate holographic display was improved obviously after gray scale adjustment. The results are helpful for the display of computer generated hologram based on digital micro-mirror device.
  • 加载中
  • [1]

    HOU R N, YAN Y F. Elimination method of zero-order image and conjugate image of off-axis digital hologram[J]. Laser Technology,2012,36(5):632-635(in Chinese).
    [2]

    WANG Zh L, ZHANG Y A, QIAN X F. Research of reconstruction of temperature field by means of digital holography and Radon transform[J]. Laser Technology,2011,35(5):589-592(in Chinese).
    [3]

    JIAN X Zh, ZHANG H, FAN J P, et al. Research of computer-generated hologram based on FPGA technology[J]. Laser Technology,2012,36(1):26-32(in Chinese).
    [4]

    SONG J, GUO X W, CHEN M Y, et al. Research on hologram reconstruction using DMD[J]. Journal of Sichuan University(Na-tural Science Edition),2008,45(3):576-580(in Chinese).
    [5]

    FAHRI Y, HOONJONG K, LEVENT O. State of the art in holographic displays: a survey[J]. Journal of display technology,2010,6(5):443-454.
    [6]

    LI J Ch, SONG Q H, GUI J B. Theory research on fresnel diffraction hologram display with DMD[J]. Acta Photonica Sinica,2009,38(6): 1459-1463(in Chinese).
    [7]

    GUO X W, DU J L, LUO B L, et al. Imaging model for DMD-based gray-tone lithography system[J]. Acta Photonica Sinica,2006,35(9): 1412-1416(in Chinese).
    [8]

    HU T. Enhance holographic reconstructed image displayed by DMD[D]. Kunming: Kunming University of Science and Technology Master Degree Dissertation,2010:29-33(in Chinese).
    [9]

    LUCENTE M. Interactive computation of holograms using a look-up table[J]. Journal of Electronic Imaging,1993,2(1): 28-34.
    [10]

    GAO Zh Q, LI Y. Relationship of image quality of digital hologram and grey level adjustment[J]. Acta Photonica Sinica,2011,40(3):327-331(in Chinese).
    [11]

    WEI T, ZHU J H, CHEN L G, et al. Digital holographic display based on digital micro-mirror device and quality enhancement of its reconstructed image[J]. Acta Photonica Sinica,2008,37(5):952-956(in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3338) PDF downloads(698) Cited by()

Proportional views

Reconstruction quality enhancement of computer generated hologram based on digital micro-mirror device

    Corresponding author: ZHANG Ya-ping, yaping.zhang@gmail.com
  • 1. Faculty of Science, Kunming University of Science and Technology, Kunming 650500, China

Abstract: In order to achieve high-quality hologram reconstruction based on digital micro-mirror device(DMD), gray scale adjustment characteristics and Fresnel diffraction characteristics of DMDs were described in detail. Then, the principle of holographic display based on DMD was analyzed. Finally, high-quality hologram was reconstructed. The results demonstrate holographic display was improved obviously after gray scale adjustment. The results are helpful for the display of computer generated hologram based on digital micro-mirror device.

Reference (11)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return