Advanced Search

ISSN1001-3806 CN51-1125/TN Map

Volume 38 Issue 4
May  2014
Article Contents
Turn off MathJax

Citation:

Study on error signal of quadrant detectors in laser seekers

  • Received Date: 2013-07-30
    Accepted Date: 2013-08-22
  • In order to study effect of error signal of a quadrant detector on detection positioning accuracy of a laser seeker, based on the detection and position principles of a quadrant detector, the influence of size of light spot, width of division line and intensity of background light on error signal was studied by means of computer simulation. The results show that bigger size of the light spot will decrease the sensitivity of a quadrant detector and extend the dynamic range. Narrower width of division line is optimal under the condition of good crosstalk performance. The background light will decrease the performance of detector. The study is helpful to improve the detection positioning accuracy of quadrant detectors in laser seekers.
  • 加载中
  • [1]

    WANG W F, LIU Z G, WANG S C, et al. Design of energy simulation system for laser guided weapons [J].Laser Technology, 2012, 36(6): 844-848(in Chinese).
    [2]

    WANG K B. Status quo, key technology and development of laser guided weapon [J].Infrared and Laser Engineering, 2007, 36(5): 651-655(in Chinese).
    [3]

    WANG K B. Latest development and trends of semi-active laser guidance technology [J].Infrared and Laser Engineering, 2008, 37(9): 275-279(in Chinese).
    [4]

    XU D S. Optimal design for signal light spot of detecting systems with quadrant detectors [J].Journal of Hunan Institute of Science and Technology (Natural Sciences Edition), 2007, 20(1): 50-53(in Chinese).
    [5]

    GAO Z J, ZHANG A J, SHI G H. Simulation study on the seeker of aerodynamically stabilized laser-guided aerial bomb [J].Opto-Electronic Engineering, 2007, 34(1): 4-8(in Chinese).
    [6]

    HU X L, ZHOU S C. Analysis and research on several angle-measurement algorithms based on four-quadrant detector [J].Laser & Infrared, 2007, 37(6): 546-547(in Chinese).
    [7]

    CUI R J, WANG J W, LI X M. Model error analysis of quadrant photodetector [J].Laser & Infrared, 2011, 41(5): 516-519(in Chinese).
    [8]

    CHEN Y, ZHU T R, LI H G. Analysis and improvement in angle-measurement algorithm of the four-quadrant detector [J].Laser & Infrared, 2009, 39(6): 669-672(in Chinese).
    [9]

    CHEN Y, ZHU T R, LI R. Design and realization of the angle-measurement algorithm of the four-quadrant detector based on the interpolation algorithm [J]. Infrared and Laser Engineering, 2011, 40(3): 544-547(in Chinese).
    [10]

    KUANG C F, FENG Q B, LIU B. Study on background light influences on four-quadrant detector [J].Laser & Infrared, 2004, 34(6): 493-495(in Chinese).
    [11]

    LI S W,ZHANG J L, HAO J, et al. Elimination of the interference of bias light for laser warning systems [J]. Laser Technology, 2012, 36(5): 642-644(in Chinese).
    [12]

    HAN C, BAI B X, YANG H M, et al. Study four-quadrant detector in the free space laser communication [J].Chinese Journal of Lasers, 2009, 36(8): 2030-2034(in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3127) PDF downloads(546) Cited by()

Proportional views

Study on error signal of quadrant detectors in laser seekers

  • 1. Luoyang Electronic Equipment Test Center of China, Luoyang 471003, China

Abstract: In order to study effect of error signal of a quadrant detector on detection positioning accuracy of a laser seeker, based on the detection and position principles of a quadrant detector, the influence of size of light spot, width of division line and intensity of background light on error signal was studied by means of computer simulation. The results show that bigger size of the light spot will decrease the sensitivity of a quadrant detector and extend the dynamic range. Narrower width of division line is optimal under the condition of good crosstalk performance. The background light will decrease the performance of detector. The study is helpful to improve the detection positioning accuracy of quadrant detectors in laser seekers.

Reference (12)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return