  • Available measurement methods of laser beam quality can't reach the demands of speed and accuracy simultaneously. In order to take speed and precision into account, a double-slit scanning method was proposed. The complexity of data analysis reduced because attenuator was not used in the optical path. Embedded technology was selected to control and process the data, and real time data processing can be realized while the whole system was easy to carry. After theoretical analysis and experimental verification, the results show that this method can get fast synchronous measurement of dual axis shaft power distribution. Dynamic range can reach 70dB and scan rate is from 2Hz to 18Hz. This method can be used for the analysis of continuous or pulsed laser beam and is helpful for reaching the demands of both measurement speed and accuracy.
  • 加载中
  • [1]

    GAO Y, FAN Z W, YU J, et al. New algorithm for measuring flat spot and Gaussian radius knife edge method[J]. Laser Technology, 2013,37(2): 261-264(in Chinese).
    [2]

    HUANG D, QIU F S. Study on characteristics of spot radius and curvature radius of generalized Gaussian beam[J]. Laser Technology, 2013,37(2): 256-260(in Chinese).
    [3]

    SOO C.Quality factors of a slightly inclined Gaussian beam passing through a zone plate: effect of stop shifts[J].International Journal for Light and Electron Optics,2013,124(17):2771-2776.
    [4]

    HE Y X, MU B L, LI J, et al. Relationship between Gaussian beam quality and wavefront aberration[J]. Laser Technology, 2014,38 (6): 747-752(in Chinese).
    [5]

    HE Y X,LI X Y. CCD photoelectric effect of nonlinear characteristics of far field laser focal spot beam quality measurement and calculation[J]. Chinese Journal of Lasers, 2012,39(4): 0408001(in Chinese).
    [6]

    SU P, NIU Y X, LI D Q, et al. Image acquisition and processing of a laser warning system based on planar array CCD[J]. Laser Technology, 2013,37(3): 394-399(in Chinese).
    [7]

    ZHANG Ch, WANG B, LIAO Zh Y, et al. Experimental study on disturbing effect of pulsed laser against array CCD imaging systems[J]. Laser Technology,2014,38(5): 619-622 (in Chinese).
    [8]

    WANG Y P, WANG Q Q, MA C. The influence factors of accurate measurement of CCD camera based on the width of the laser beam[J]. Chinese Journal of Lasers, 2014,41(2):0208002(in Chinese).
    [9]

    DONG F L, ZHAO F Z, GE Y W, et al. The optimization of laser beam quality of full optical fiber[J]. Optics and Precision Engineering, 2014,22(4): 844-849(in Chinese).
    [10]

    ZHANG H Zh, YAO M, LEI P, et al. Research of image processing method of far-field laser spots[J]. Laser Technology,2013,37(4): 460-463 (in Chinese).
    [11]

    QIU K, FAN Z W, XIONG X T. Technology research of super Gauss flattened distribution spatial beam shaping[J]. Journal of Optoelectronics Lasers, 2014,25(2): 233-238(in Chinese).
    [12]

    KANOLD P O, LSRAEL N, POLLEY D B, et al. Local versus global scales of organization in auditory cortex[J]. Review Article Trends in Neurosciences, 2014,37(9):502-510.
    [13]

    HUANG L H, LIAO X B, ZHAO H Y, et al. The use of beam quality analyzer to measure M2 factor[J].Infrared and Laser Engineering. 2012,41(8): 2197-2120 (in Chinese).
    [14]

    JIN A J, HOU J, JIANG Z F. Using the evaluation of supercontinuum M2 supercontinuum source beam quality factor[J]. Chinese Journal of Lasers, 2013,40(5):0502006(in Chinese).
    [15]

    LIU F H, JI Y F, WANG F. Development of laser beam quality measurement system[J]. Application of Modern Physics, 2014, 5 (3): 182-186(in Chinese).
    [16]

    MA Z W, WEI T, FENG G Y. Theoretical analysis of the beam quality of two-side-pumped symmetrically transverse flow liquid lasers[J].Laser Technology,2011,35(4): 543-546(in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(9152) PDF downloads(454) Cited by()

Proportional views

Measurement of laser beam quality by means of double-slit scanning method

    Corresponding author: ZANG Jingfeng, lileihoney521@126.com
  • 1. School of Electronics and Information Engineering, Changchun University of Science and Technology, Changchun 130022, China

Abstract: Available measurement methods of laser beam quality can't reach the demands of speed and accuracy simultaneously. In order to take speed and precision into account, a double-slit scanning method was proposed. The complexity of data analysis reduced because attenuator was not used in the optical path. Embedded technology was selected to control and process the data, and real time data processing can be realized while the whole system was easy to carry. After theoretical analysis and experimental verification, the results show that this method can get fast synchronous measurement of dual axis shaft power distribution. Dynamic range can reach 70dB and scan rate is from 2Hz to 18Hz. This method can be used for the analysis of continuous or pulsed laser beam and is helpful for reaching the demands of both measurement speed and accuracy.