Advanced Search

ISSN1001-3806 CN51-1125/TN Map

Volume 40 Issue 6
Sep.  2016
Article Contents
Turn off MathJax

Citation:

Quantitative analysis of composition in molten steel by LIBS based on improved partial least squares

  • Received Date: 2015-10-09
    Accepted Date: 2015-10-28
  • In order to study the effect of laser induced breakdown spectroscopy (LIBS) matrix effect on measurement accuracy, the improved partial least squares (PLS)was used to forecast the data and reduce the influence of matrix effect on the to-be-detected parameters. The comparative study with univariate calibration and partial least squares model calibration shows that the fitting degree of calibration curves of Mn and Si improve from 0.991 and 0.993 to 0.996 and 0.997, and the relative error of prediction for validation samples were decreased from 6.231%, 6.912% to 5.510%, 6.125%.The above results show that the improved PSL can reduce matrix effects and improve the calibration accuracy. The analysis of performance has been improved significantly.
  • 加载中
  • [1]

    WANG Ch H, DAI L, ZHANG X, et al. Laser induced breakdown spectroscopy of AlCl3 aqueous aolution[J].Chinese Jouranl of Lasers,2006,33(9):1190-1194(in Chinese).
    [2]

    LIU L.Stability improvement of laser-induced breakdown spectroscopy based on dual-line internal standard[J].Laser Technology,2015,39(1):90-95(in Chinese).
    [3]

    WAN X Y, WANG Y G, XIONG Y, et al. classification and determination of chromium in stream sediment by laser-induced breakdown spectroscopy[J].Laser Journal,2014,35(4):43-44(in Chinese).
    [4]

    LI J. Mechanism study of measurement of coal quality by laser-induced breakdown spectroscopy[D]. Wuhan:Huazhong University of Science and Technology,2010:90-99(in Chinese).
    [5]

    CIUCCI A, CORSI M, PALLESCHI V, et al.New procedure for quantitative elemental analysis by laser-induced plasma spectroscopy[J]. Applied Spectroscopy, 1999, 53(8):960-964.
    [6]

    LEGNAIOLI S, LORENZETTI G, PARDINI L, et al. Laser-induced breakdown spectroscopy application to control of the process of precious metal recovery and recycling[J]. Spectrochimica Acta Part B:Atomic Spectroscopy,2012,71/72(5/6):123-126.
    [7]

    SUN L X, YU H B, CONG Zh B.On-line semi-quantitative analysisof molten steel composition using laser-induced break down spectroscopy[J].Chinese Journal of Scientific Instrument,2011,32(11):2602-2608(in Chinese).
    [8]

    CHEN X L, DONG F Zh,WANG Q, et al.quantitative analysis of slag by calibration-free laser induced break down spectroscopy[J]. Spectroscopy and Spectral Analysis,2011,31(12):3289-3293(in Chinese).
    [9]

    WANG Sh L, WANG Y G, CHEN Q, et al.quantitative analysis of metal elements in crude oil by means of laser induced breakdown spectroscopy[J].Laser Technology,2015,39(1):104-108(in Chinese).
    [10]

    MOHAMED W T Y. Improved LIBS limit of detection of Be, Mg, Si, Mns Fe and Cu in aluminum alloy samples using a portable echelle spectrometer with ICCD camera[J]. Optics and Laser Technology, 2008,40(1):30-38.
    [11]

    LI Y.Quantitative analysis of metal elements using LIBS and Its relevant impact factors[D]. Qingdao:Ocean University of China,2011:76-78(in Chinese).
    [12]

    CONG Zh B, SUN L X, XIN Y, et al. Quantitative analysis of alloy stell based on laser induced breakdown spectroscopy with partial least squares method[J].Spectroscopy and Spectral Analysis,2014,34(2):542-547(in Chinese).
    [13]

    LUO P, GUO J Ch, LI Q, et al. Discussion based on partial least squares regression model[J].Journal of Tianjin University,2002,35(6):783-786(in Chinese).
    [14]

    LU H T.Partial least squares regression models and algorithms research[D].Baoding:North China Electric Power University,2014:4-21(in Chinese).
    [15]

    JIANG W H, XIA J L. Partial least square and its application[J].Journal of The Fourth Military Medical University, 2003,21(3):280-283(in Chinese).
    [16]

    XU F H, LI Sh Sh, ZHANG Y. Multiple dependent variables based on double screening partial least squares regression method[J].Statistic Decision,2008,256(4):25-27(in Chinese).
    [17]

    SONG G Y. Some studies about partial least squares regression[D].Hangzhou:Zhejiang University,2009:20-23(in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(5649) PDF downloads(244) Cited by()

Proportional views

Quantitative analysis of composition in molten steel by LIBS based on improved partial least squares

  • 1. Science and Technology, North China University, Tangshan 063000, China

Abstract: In order to study the effect of laser induced breakdown spectroscopy (LIBS) matrix effect on measurement accuracy, the improved partial least squares (PLS)was used to forecast the data and reduce the influence of matrix effect on the to-be-detected parameters. The comparative study with univariate calibration and partial least squares model calibration shows that the fitting degree of calibration curves of Mn and Si improve from 0.991 and 0.993 to 0.996 and 0.997, and the relative error of prediction for validation samples were decreased from 6.231%, 6.912% to 5.510%, 6.125%.The above results show that the improved PSL can reduce matrix effects and improve the calibration accuracy. The analysis of performance has been improved significantly.

Reference (17)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return