Advanced Search

ISSN1001-3806 CN51-1125/TN Map

Volume 13 Issue 6
Sep.  2013
Article Contents
Turn off MathJax

Citation:

The heat-exchanger used in cooling 100 W Nd:YAG laser

  • Received Date: 1989-01-31
  • The heat-exchanger used in cooling 100 W Nd:YAG laser is introduced.In this paper the thermodynamical computation,mechanical structure,experiment and application on the heat-exchanger are described.
  • 加载中
  • 、[2] 《工程时流换热》,机械工业出版社,北京,1982年.

  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(2652) PDF downloads(268) Cited by()

Proportional views

The heat-exchanger used in cooling 100 W Nd:YAG laser

  • 1. Southwest Institute of Technical Physics

Abstract: The heat-exchanger used in cooling 100 W Nd:YAG laser is introduced.In this paper the thermodynamical computation,mechanical structure,experiment and application on the heat-exchanger are described.

Reference (1)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return