Experimental research of X-ray preionization source for excimer lasers

  • Received Date: 1995-06-12
  • In order to obtain the homogeneity of pulse discharge at the high pressure,a X-ray preionization source for excimer lasers is introduced in this paper.The X-ray results from the impact of accelerated electrons against a Tatarget.The shorter the wavelength of X-ray is,the ability of the preionization is much stronger.With the X-ray preionization source,the preionization electrons density of 2.9×108cm-3 can be obtained in He:Xe:Fe mixed gas atmosphere.
  • 加载中
  • [1]

    Levatter J I,Lin S C.J A P,1980;51(1):210
    [2] H-J.奎瑟主编.X射线光学在固体领域中的应用.北京:科学出版社,1985

    [3]

    Midorikaw a K.IEEE J Q E,1984;QE-20(3):198
    [4]

    Sumida S.A P L,1978;33(11):913
    [5] 黄胜涛主编.固体X射线学.北京:高等教育出版社,1985

    [6]

    Levatter J I.Adissertation for the degree Dooctor of Philosophy.San Diego:University of California,1979
    [7]

    Levatter J I,Li Z G.Rev Scient Instrum,1981;52(11):1651~1654
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(2777) PDF downloads(376) Cited by()

Proportional views

Experimental research of X-ray preionization source for excimer lasers

  • 1. National Lab.of Laser Tech., HUST

Abstract: In order to obtain the homogeneity of pulse discharge at the high pressure,a X-ray preionization source for excimer lasers is introduced in this paper.The X-ray results from the impact of accelerated electrons against a Tatarget.The shorter the wavelength of X-ray is,the ability of the preionization is much stronger.With the X-ray preionization source,the preionization electrons density of 2.9×108cm-3 can be obtained in He:Xe:Fe mixed gas atmosphere.