Xenon flashlamp and its pumping properties
- Received Date: 1995-09-11
- Accepted Date: 1996-04-04
- Available Online: 1997-01-25
Abstract: In this paper,the key techniques to improve the pumping properties and reliability of Xenon flash lamp are summarized.Especially the paper points out that the main factors effecting the pumping characteristics are selection of lamp tube and welding procedure,and the silicon tube doped with Ce and high-temperature silicon wolfram diffusing procedure are recommend.