Study on directional prism improving the output stability of Q-switched by Cr4+:YAG

  • Received Date: 2004-02-06
    Accepted Date: 2004-06-07
  • In order to improve the output stability of LD pumpe d Nd:YAG laser Q-switched by Cr4+:YAG,the directional prism resonator is used,a single smooth laser pulse has been achieved with the energy stability changing from 7.3%~2.2%,pulse-width stability changing from 13.5%~6.5%,repetition rate stability changing from 0.01%~0.005%.The experimental result shows that compared with the plano-plane resonator,the directional prism resonator improves output stability of the laser greatly.It is reported for the first time that the directional prism resonator can eliminate the tail-pulse.
  • 加载中
  • [1] 裴博,包照日格图,周昀 et al.内腔式KTP OPO发散角的实验研究[J].中国激光,2002,A29(1):13~16.

    [2] 张行愚,赵圣之,王青圃 et al.Cr4+:YAG调Q特性的理论和实验研究[J].光学学报,1998,18(9):1180~1185.

    [3] 程勇,孙斌,王小兵 et al.一种改善激光光束质量和稳定性的新途径[J].量子电子学报,1999,16(3):217~220.

    [4] 程勇,毛少卿,王志怀 et al.免调试固体激光器[J].激光技术,1999,23(2):68~70.

    [5] 吴念乐,吕亚军,陆兴华 et al.含Cr离子饱和吸收体被动调Q解析解[J].光学学报,1996,16(12):1813~1818.

    [6] 郑权,邵兰芳,赵岭 et al.Cr4+:YAG 调Q全固态激光器可控运转方法研究[J].激光与红外,2003,33(3):194~196.

    [7] 巩马理,闫平,谢韬 et al.被动Q开关激光器的预抽运技术[J].中国激光,2003,A30(7):585~589.

    [8]

    SCHOLL M S.Ray trace through a corner-cube retro-reflector with complex reflection coefficients[J].J O S A,1995,12(7):1589~1592.
    [9]

    WANG Sh M,ZHAO D M,HU L G et al.Corner cube recognized as super-conjugator[J].Proc SPIE,2002, 4914:182~187.
    [10] 王小兵,孙斌,程勇 et al.定向棱镜谐振腔的平顶高斯光束特性[J].激光技术,2002,26(2):117~122.

    [11] 宋晏蓉,李瑞宁,刘媛媛 et al.用Cr4+:YAG作调Q元件的激光器特性的研究[J].中国激光,2001,28(6):487~490.

  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(2586) PDF downloads(460) Cited by()

Proportional views

Study on directional prism improving the output stability of Q-switched by Cr4+:YAG

  • 1. Facility of Opto-electronics, Wuhan Ordnance Non-commissioned Officers Academy, Wuhan 400075, China

Abstract: In order to improve the output stability of LD pumpe d Nd:YAG laser Q-switched by Cr4+:YAG,the directional prism resonator is used,a single smooth laser pulse has been achieved with the energy stability changing from 7.3%~2.2%,pulse-width stability changing from 13.5%~6.5%,repetition rate stability changing from 0.01%~0.005%.The experimental result shows that compared with the plano-plane resonator,the directional prism resonator improves output stability of the laser greatly.It is reported for the first time that the directional prism resonator can eliminate the tail-pulse.

Reference (11)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return