Advanced Search

ISSN1001-3806 CN51-1125/TN Map

Volume 30 Issue 4
Sep.  2013
Article Contents
Turn off MathJax

Citation:

Experimental parameters choice of photo-thermal interferometric detection system

  • Received Date: 2005-06-08
    Accepted Date: 2005-07-04
  • In order to study influence of experimental parameters on photo-thermal interferometric detection,according to interference principle of equal thickness,a theory model is set up by means of Seidel aberration of tilt.After various probe beams are investigated,a universal light model is proposed by means of random function,and uniformity of the light source is defined.Based on this model,it is simulated that interferometric experimental phenomena change with various probe beam,and the influence of probe's uniformity is analyzed on interferometric measurement,which show there are no difference among various probe beam.On the other hand,the influence of detector's aperture on interferometric measurement is analyzed.Results show it is the best when radius of detector's aperture is 0.315cm.Under this condition,photo-thermal signal descends monotonously during fine scale photo-thermal displacement of 0~0.6λ,and the contrast of interferometric stripe is better.Under weak absorption,a simple experiential equation between photo-thermal signal and photo-thermal displacement can be concluded by curve fitting.
  • 加载中
  • [1]

    WEI H Zh,LI J R.Measurement of optical component absorption[J].Laser Technology,1999,23(5):284~287(in Chinese).
    [2]

    ZHANG Zh J.A new method for the study of optical and thermal properties of surfaces:photo-thermal displacement spectroscopy[J].Acta Photonica Sincia,1996,25(7):585~588(in Chinese).
    [3]

    YIN Q R,WANG T,QIAN M L.Photoacoustic photo-thermal technology and its aplliacations[M].Beijing:Science Press,1999.176~180(in Chinese).
    [4]

    LI B Ch,DENG Y Zh,CHENG J K.Anovel interferometric detection scheme for photothermal measurements[J].Chinese Journal of Lasers,1997,24(12):1085~1089(in Chinese).
    [5]

    HU H Y,FAN Zh X,ZHAO Q.Measureing weak absorptance of thin film coatings by surface thermal lensing technique[J].Acta Optica Sinica,2001,21(2):150~154(in Chinese).
    [6]

    WANG Y J,HU H Y,LI Q G et al.Study of weak absorption of the thin films coated on the Si plates[J].Chinese Journal of Lasers,2001,A28(10):937~940(in Chinese).
    [7]

    YANG F,HUANG W,ZHANG B et al.Temperature field distribution and thermal distortion of thin film coatings irradiated by CO2 laser[J].Laser Technology,2004,28(3):255~258(in Chinese).
    [8]

    YANG F,HUANG W,ZHANG B et al.Measurement of weak absorption of thin film coatings irradiated by 10.6μm laser[J].High Power Laser and Particle Beams,2004,16(3):277~280(in Chinese).
    [9]

    JING T J,HUANG W,QI W Z et al.Tin film weak absorption of 3.8μm and 2.8μm laser measured by surface thermal lensing technique[J].High Power Laser and Particle Beams,2004,16(12):1497~1500(in Chinese).
    [10]

    POWER J F.Pulsed mode thermal lens effect detection in the field via thermally induced probae beam spatial phase modulation:a theory[J].Appl Opt,1990,29(1):52~63.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(2762) PDF downloads(268) Cited by()

Proportional views

Experimental parameters choice of photo-thermal interferometric detection system

  • 1. Institute of Applied Electronic, CAEP, Mianyang 621900, China

Abstract: In order to study influence of experimental parameters on photo-thermal interferometric detection,according to interference principle of equal thickness,a theory model is set up by means of Seidel aberration of tilt.After various probe beams are investigated,a universal light model is proposed by means of random function,and uniformity of the light source is defined.Based on this model,it is simulated that interferometric experimental phenomena change with various probe beam,and the influence of probe's uniformity is analyzed on interferometric measurement,which show there are no difference among various probe beam.On the other hand,the influence of detector's aperture on interferometric measurement is analyzed.Results show it is the best when radius of detector's aperture is 0.315cm.Under this condition,photo-thermal signal descends monotonously during fine scale photo-thermal displacement of 0~0.6λ,and the contrast of interferometric stripe is better.Under weak absorption,a simple experiential equation between photo-thermal signal and photo-thermal displacement can be concluded by curve fitting.

Reference (10)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return