Advanced Search

ISSN1001-3806 CN51-1125/TN Map

Volume 32 Issue 2
Apr.  2010
Article Contents
Turn off MathJax

Citation:

Reconstruction with collimating reference wave in digital holography microscopy

  • Corresponding author: WANG Da-yong, wdyong@biut.edu.cn
  • Received Date: 2006-12-25
    Accepted Date: 2007-06-04
  • In order to reconstruct three-dimension micro-object wave field accurately,the reconstruction method with collimating reference wave to reconstruct digital hologram with large numerical aperture was studied by using Fresnel diffraction formula and sampling theorem.The reason that spherical reference wave can't be used to reconstruct a large numerical aperture hologram was analyzed.The expression of reconstructed phase image was presented.As result of the measure error of the recording distance and the offset of the point source,the distortion of the phase image reconstructed with collimating reference wave was also analyzed.Both theoretical analysis and computer simulation show that accurate intensity reconstruction can be obtained as long as a high quality hologram is recorded.Only if the recording distance and the offset of the point source are accurately measured,the correct phase reconstruction can be obtained.Due to a measure error,a quadratic function distortion of the reconstructed phase distribution appears.So it is important to measure the recording parameters accurately in experiment.
  • 加载中
  • [1]

    WAGNER C,SEEACHER S,OSTEN W,et al.Digital recording and numerical reconstruction of lensless Fourier holograms in optical metrology[J].Appl Opt,1999,28(22):4812-4819.
    [2]

    DIRKSEN D,DROSTE H,KEMPER B,et al.Lensless Fourier holography for digital holographic interferometry on biological samples[J].Optics & Lasers in Engineering,2001,36(3):241-249.
    [3]

    LÜ Q N,GE B Z,ZHANG Y M,et al.Progress of studies on digital holography and its application in particle field[J].Journal of Optoelectronics ·Laser,2002,13(10):1087-1091(in Chinese).
    [4]

    GUSTAFSSON M,SEBESTA M,BENGTSSON B,et al.High-resolution digital transmission microscopy-a Fourier holography approach[J].Optics & Lasers in Engineering,2004,41(3):553-563.
    [5]

    NOVAK E.MEMS metrology techniques[J].SPIE,2005,5716:173-181.
    [6]

    FAN Q,ZHAO J L,XIANG Q,et al.Methods of improving resolution of digital holography[J].Journal of Optoelectronics·Laser,2005,16(2):226-230(in Chinese).
    [7]

    PEDRINI G,FRONING P,TINIANE H J,et al.Shape measurement of microscopic structure using digital holograms[J].Opt Commun,1999,164:257-268.
    [8]

    LÜ Q N,GE B Z,ZHANG Y M.Analysis of the influence factors of the reconstructed image quality in digital holography[J].Journal of Optoelectronics·Laser,2005,16(1):83-88(in Chinese).
    [9]

    YUAN C J,ZHONG L Y,WANG Y P,et al.The analysis of off-axis digital holographic recording conditions[J].Laser Technology,2004,28(5):482-485(in Chinese).
    [10]

    WANG H Y,WANG D Y,XIE J J,et al.Study of the reconstructing methods of the digital off-axis lens-less Fourier transform hologram[J].Laser Technology,2007,31(3):288-290(in Chinese).
    [11]

    WANG H Y,WANG D Y,XIE J J,et al.Recording conditions of digital holography[J].SPIE,2007,6279:62791J(1-10).
    [12]

    GUO Y Z,QIU Z M,LI X,et al.A method of tuning focus for image measurement technology[J].Journal of Xi'an University of Technology,2001,17(1):40-42(in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3283) PDF downloads(192) Cited by()

Proportional views

Reconstruction with collimating reference wave in digital holography microscopy

    Corresponding author: WANG Da-yong, wdyong@biut.edu.cn
  • 1. College of Applied Sciences, Beijing University of Technology, Beijing 100022, China;
  • 2. Henan Institute of Metrology, Zhengzhou 450008, China;
  • 3. College of Science, Hebei University of Engineering, Handan 056038, China

Abstract: In order to reconstruct three-dimension micro-object wave field accurately,the reconstruction method with collimating reference wave to reconstruct digital hologram with large numerical aperture was studied by using Fresnel diffraction formula and sampling theorem.The reason that spherical reference wave can't be used to reconstruct a large numerical aperture hologram was analyzed.The expression of reconstructed phase image was presented.As result of the measure error of the recording distance and the offset of the point source,the distortion of the phase image reconstructed with collimating reference wave was also analyzed.Both theoretical analysis and computer simulation show that accurate intensity reconstruction can be obtained as long as a high quality hologram is recorded.Only if the recording distance and the offset of the point source are accurately measured,the correct phase reconstruction can be obtained.Due to a measure error,a quadratic function distortion of the reconstructed phase distribution appears.So it is important to measure the recording parameters accurately in experiment.

Reference (12)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return