  • Corresponding author: QIAO Xue-guang, qiaoxueguang@xsyu.edu.cn
  • Received Date: 2005-12-15
    Accepted Date: 2006-02-15
  • To improve the sensitivity of temperature sensor and pressure sensor so that they are applicable,the fiber Bragg grating(FBG) temperature sensor and FBG pressure sensor are encapsulated.The temperature sensitivity of the FBG temperature sensor is(0.052nm/℃) and the pressure sensitivity of the FBG pressure sensor is 0.8208nm/MPa from the experimental results.The temperature sensitivity and pressure sensitivity is 5.2 times and 273 times of that of bare FBG.The temperature and pressure response curve of FBG sensor is linear with reflective wavelength of FBG.After the FBG sensing system is used to detect the temperature and pressure of oil in pipeline about half month,the experimental results are consistent with those of electric sensor.The FBG sensing system can be used in pipeline on-line measurement.
  • 加载中
  • [1]

    JIA Zh A,QIAO X G,LI M et al.The influence of temperature on reflected wavelength shift of fiber Bragg gratings[J].Laser Technology,2004,28 (3):309~311 (in Chinese).
    [2]

    XIE F,ZHANG Sh L,LI Y et al.Study on the reflected wavelength shift based on sensing elements of in-fiber Bragg gratings[J].Laser Technology,2002,26(2):84~86(in Chinese).
    [3]

    ZHANG W G,KAI G Y,DONG X Y et al.Theoreretical and experimental study of fiber grating multi-point sensing[J].Acta Optica Sinica,2004,24 (3):330~336 (in Chinese).
    [4]

    GAO J Q,SHI B,ZHANG W et al.Application of distributed fiber optic sensor to bridge and pavement health monitoring[J].Journal of Disaster Prevention and Mitigation Engineering,2005,25 (1):14~19(in Chinese).
    [5]

    XIA Y Y,RUI R,LIANG L et al.An attempt of embedding fiber optic Bragg grating sensors in freeway foundation to detect the pore-water pressure[J].Chinese Journal of Geotechnical Engineering,2005,27(2):162~166(in Chinese).
    [6]

    XIN S J,FAN W P.Research on durability detecting of high performance concrete structure with fiber grating sensor[J].Journal of Wuhan University of Technology,2005,27 (6):32~34 (in Chinese).
    [7]

    LIAO Y B.Fiber of optics[M].Beijing:Tsinghua University Press,2000.198~204(in Chinese).
    [8]

    FU H W,FU J M,QIAO X G et al.Study about the stress sensitivity enhancement of fiber Bragg gratings[J].Laser Technology,2005,29(2):159~161 (in Chinese).
    [9]

    WANG L B,ZHANG B M,WANG D F et al.A kind of fiber Bragg grating strain sensor with jacket[J].Laser Technology,2002,26 (5):385~387(in Chinese).
    [10]

    SUN A,QIAO X G,JIA Zh A et al.Temperature and pressure responsive characteristics of polymer packaged fiber Bragg grating with large dynamic range[J].Chinese Journal of Lasers,2005,32 (2):224~227 (in Chinese).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article views(3127) PDF downloads(484) Cited by()

Proportional views

The fiber Bragg grating temperature and pressure sensing system applied in oil pipeline

    Corresponding author: QIAO Xue-guang, qiaoxueguang@xsyu.edu.cn
  • 1. Shanxi Key Laboratory of Photoelectric Sensing Logging, Xi'an Shiyou University, Xi'an 710065, China

Abstract: To improve the sensitivity of temperature sensor and pressure sensor so that they are applicable,the fiber Bragg grating(FBG) temperature sensor and FBG pressure sensor are encapsulated.The temperature sensitivity of the FBG temperature sensor is(0.052nm/℃) and the pressure sensitivity of the FBG pressure sensor is 0.8208nm/MPa from the experimental results.The temperature sensitivity and pressure sensitivity is 5.2 times and 273 times of that of bare FBG.The temperature and pressure response curve of FBG sensor is linear with reflective wavelength of FBG.After the FBG sensing system is used to detect the temperature and pressure of oil in pipeline about half month,the experimental results are consistent with those of electric sensor.The FBG sensing system can be used in pipeline on-line measurement.