高级检索

相机和到达角基站间的外参标定

Extrinsic parameter calibration of a camera and an AoA anchor

  • 摘要: 为了填补相机和到达角(AoA)基站间的外参标定领域的研究空白,使用棋盘格标定板,从图像中提取标签位置,基于两种传感器数据之间的几何约束来计算最优外参, 并进行了理论分析和实验验证,取得了仿真和实验数据。结果表明,采用该方法得到的标定结果, 距离误差在0.08 m以内,角度误差在3.5°以内。该研究对相机和AoA基站间的外参标定以及机器人感知系统设计是有帮助的。

     

    Abstract: In order to fill the research gap in the field of external parameter calibration between the camera and the angle of arrival (AoA) base station, the checkerboard calibration board was used to extract the label position from the image, and the optimal external parameter was calculated based on the geometric constraint between the two sensor data. Theoretical analysis and experimental verification were carried out, and the simulation and experimental data were obtained. The results show that, the distance error of the calibration results obtained by this method is within 0.08 m, and the angle error is within 3.5°. The research is helpful for the calibration of external parameters between camera and AoA base station and the design of robot sensing system.

     

/

返回文章
返回