Research of detection of aerosol extinction coefficient based on pulse cavity ring-down technology
-
摘要: 为了高灵敏度地测量气溶胶消光系数,采用高反射率腔镜以及脉冲腔衰荡的方法,搭建了气溶胶消光系数检测装置。对不同条件下的实际大气进行了测量,对实验结果进行了分析和研究,并与国内外研究成果进行比较。结果表明,由实验装置测量的腔衰荡时间大于40s,稳定性优于0.3%,探测灵敏度大于1.810-7m-1。高反射率腔镜及脉冲腔衰荡方法在研制高灵敏度气溶胶消光系数检测装置中具有较强的可行性。Abstract: In order to measure aerosol extinction coefficients with higher sensitivity, a system for measuring aerosol extinction coefficients was set up based on high-reflectivity cavity mirrors and pulse cavity ring-down technology. The actual atmosphere under different conditions was measured. The experimental results were analyzed and studied, and compared with the research results at home and abroad. The results of the experiment show that cavity ring-down time is greater than 40s, stability is better than 0.3% and detection sensitivity is greater than 1.810-7m-1. Cavity mirrors with high reflectivity and pulse cavity ring-down technology are quite feasible in development of detection systems of aerosol extinction coefficients with high sensitivity.
-
Keywords:
- atmospheric optics /
- extinction coefficient /
- cavity ring-down /
- sensitivity /
- aerosol
-
-
[1] BO G Y, ZHONG Z Q, WANG B X, et al. Retrieval of aerosol and cloud optical parameters based on Raman lidars[J]. Laser Technology, 2012, 36(5):597-601(in Chinese).
[2] YANG H, LIU W Q, LIU J G, et al. Monitoring and study of city tropospheric aerosol[J]. Laser Technology, 2006, 30(2):174-176(in Chinese).
[3] YAN S S, HU S X, HU H L, et al. Uncertainty analysis of aerosol wavelength exponent measured by Raman-Mie lidars[J]. Laser Technology, 2008, 32(6):667-672(in Chinese).
[4] O'KEEFE A, DEACON D A G. Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources[J]. Review of Scientific Instruments, 1988, 59(12):2544-2551.
[5] WANG C, SAHAY P. Breath analysis using laser spectroscopic techniques:Breath biomarkers, spectral fingerprints, and detection limits[J]. Sensors, 2009, 9(10):8230-8262.
[6] BUSCH K W, BUSCH M A. Cavity-ringdown spectroscopy:an ultratrace-absorption measurement technique[M]. Washington DC,USA:American Chemical Society, 1999:720.
[7] TAN Z Q, LONG X W. Fast data fitting in the application of cavity ring-down technology[J]. Laser Journal, 2007, 28(4):20-21(in Chinese).
[8] ZHAO H T, LIU X J, ZHAN M S. Cavity ring-down spectroscopy and high sensitivity absorption measurement[J]. Physics, 2001, 30(4):217-219(in Chinese).
[9] SUN J Q. The relationship between visibility and relative humidity[J]. Acta Meteorologica Sinica, 1985, 43(2):230-234(in Chinese).
[10] KANG M L. Design of breath acetone analyzer based on cavity ring-down spectroscopy[D]. Tianjin:Tianjin Medical University, 2013:28-29(in Chinese).
[11] WANG C, SURAMPUDI A B. An acetone breath analyzer using cavity ring down spectroscopy:an initial test with human subjects under various situations[J]. Measurement Science and Technology, 2008, 19(10):105604.
[12] XUE H, KHALIZOV A F, WANG L, et al. Effects of dicarboxylic acid coating on the optical properties of soot[J]. Physical Chemistry Chemical Physics, 2009, 11(36):7869-7875.
[13] SMITH J D, ATKINSON D B. A portable pulsed cavity ring-down transmissometer for measurement of the optical extinction of the atmospheric aerosol[J]. Analyst, 2001, 126(8):1216-1220.
[14] THOMPSON J E, SMITH B W, WINEFORDNER J D. Monitoring atmospheric particulate matter through cavity ring-down spectroscopy[J]. Analytical Chemistry, 2002, 74(9):1962-1967.
[15] PETTERSSON A, LOVEJOY E R, BROCK C A, et al. Measurement of aerosol optical extinction at 532nm with pulsed cavity ring down spectroscopy[J]. Journal of Aerosol Science, 2004, 35(8):995-1011.
[16] MOOSMVLLER H, VARMA R, PATRICK A W. Cavity ring-down and cavity-enhanced detection techniques for the measurement of aerosol extinction[J]. Aerosol Science and Technology, 2005, 39(1):30-39.
[17] ZHANG R, KHALIZOV A F, PAGELS J, et al. Variability in morphology, hygroscopicity, and optical properties of soot aerosols during atmospheric processing[J]. Proceedings of the National Academy of Sciences, 2008, 105(30):10291-10296.
[18] STRAWA A W, CASTANEDA R, OWANO T, et al. The measurement of aerosol optical properties using continuous wave cavity ring-down techniques[J]. Journal of Atmospheric and Oceanic Technology, 2003, 20(4):454-465.
[19] LANG-YONA N, RUDICH Y, SEGRE E, et al. Complex refractive indices of aerosols retrieved by continuous wave-cavity ring down aerosol spectrometer[J]. Analytical Chemistry, 2009, 81(5):1762-1769.
-
期刊类型引用(1)
1. 闵锐,成纯富,贺洁. 空域无源光纤腔衰荡乙炔体积分数检测仿真. 激光技术. 2023(03): 366-371 . 本站查看
其他类型引用(4)
计量
- 文章访问数: 5
- HTML全文浏览量: 0
- PDF下载量: 8
- 被引次数: 5